Run setup. Follow the installation guide for Windows Unblock and per-user or all-users options.
Reopen AutoCAD Plant 3D and your project. RKCadTools loads automatically.
Open the RKCadTools ribbon tab and start your 15-day trial from Utilities > Activate License, or activate your paid license.
No payment details are required for the trial. Confirm the trial email to create the account used for purchasing and managing seats.
Advanced: manual DLL loading
Use NETLOAD only for a manually supplied package or development build. Choose the DLL built for your Plant 3D year. Keep its companion files together; a DLL already loaded by AutoCAD cannot be replaced by loading it again. Restart Plant 3D before loading an updated build.
Start a Cable Tray route
In Plant 3D 2025–2027, open a saved millimetre or inch 3D Piping model, then choose Draw Cable Route in the Cable Tray ribbon panel.
Choose a tray product, draw the route, add supports and review the Excel bill of material.
If it still does not appear, close Plant 3D, rerun the installer and restart. See the installation guide for support details.
AutoCAD locks loaded plugin files. Close AutoCAD before replacing DLL files in a folder that is already loaded.
For normal use, use the Windows installer. It places the files for supported Plant 3D versions automatically. Use manual DLL loading only for a supplied manual package or development build.
Cable Tray adds tray and ladder routing, independent supports and Excel BOM export. Its illustrated deep dive walks through the full workflow. Color Sets, Linked P&ID Publish, Revision Manager, and Drawing List Generator are covered below. Spec Browser adds drag-and-drop insertion, Excel export, and advanced visible-column search. Data Manager adds explicit class loading, class-aware saved views, and Excel import/export. Assign Tag keeps separate P&ID and 3D field setups, while Quick Properties now uses Plant 3D’s persistent native Override state for eligible acquired properties.
Deep-Dive Guides
Open a focused walkthrough when the quick explanation is not enough.
Start with the Quick Guide for orientation. Each deep dive adds preparation, screenshots, safety checks, detailed steps, and troubleshooting for one larger workflow. You can also browse every guide from the Guides page.
Cable Tray
Draw trays and ladders, edit routes, place supports and export Excel quantities. Ten steps with all 22 screenshots.
The toolkit is grouped into task-based ribbon panels.
3D Piping ribbon
The 3D ribbon provides Spec Browser, Weld Manager, Color Rules and model clipping alongside data and delivery tools. Select the image to view it at full size.
P&ID ribbon
The P&ID ribbon adds Numbering, OPC tools, Linked P&ID Publish, Tag Audit and P&ID Palette Builder. The common panels retain the data, clipping, drawing-delivery and setup tools. Select the image to view it at full size.
Panel
Buttons
Use it for
Editing
Assign, Quick Properties, Visible Fields; Numbering in P&ID
Assign tags, edit selected-object properties and configure visible fields. The P&ID Numbering menu includes the tag, nozzle and OPC numbering actions.
3D
Spec Browser, Spec Bar, Weld Manager, Color Rules
Find spec components, number or review welds, and apply property-based model colors. Shown for 3D Piping drawings.
P&ID
OPC Manager, OPC Overview, Linked P&ID Publish
Connect and review off-page connectors, inspect the drawing network and publish linked P&ID PDFs. Shown for P&ID drawings.
Clipper
Clipper, Create Box, Quick Views, Restore Model
Isolate a model region, adjust a clipping box, switch saved views and restore the full model.
Data & Control
Data Manager, PipeLine Manager (3D), Tag Audit (P&ID), Data Validator, Data Bridge
Work with project data tables, select pipeline groups, audit tags, compare data sources and configure external-data lookup or sync.
Drawings & Delivery
Revision Manager, PID Drawing List, Reports, Export DWG, Update Attributes; A1 in the illustrated P&ID ribbon
Manage revisions, drawing lists and reports, export drawings and update attributes. Available drawing controls depend on the drawing context and configuration.
Setup & Help
Settings, User Guide, Symbol Browser and P&ID Palette Builder
Configure the toolkit, open documentation and build P&ID symbol palettes.
Data Manager
Use this when you want a table view of project data and controlled editing.
The loaded table distinguishes locked grey reference fields from green editable cells. Object edits remain pending until accepted.
Choose P&ID or 3D Piping, then choose Current drawing or Full project.
Use the Classes tab to select one or more database classes.
Click Load selected data. If you change the class selection later, load again to update the grid.
Show the fields you need
Open the Fields tab.
Use the field search box to find a property.
Tick the fields you want.
Click Apply.
Save and reuse a view
Select the required classes and fields, then arrange or hide grid columns.
Type a name in Views and click Save View.
The view stores its class selection, visible fields, filters, and column layout. Saving also applies a pending class selection.
Edit a value
Show the field in the table.
Click a green editable cell.
Type the new value.
Hover over a pending cell, or select it, to compare the previous value, new value, and change source.
Click Review changes to search all pending changes and exclude individual items if needed.
Click Accept to write the remaining changes, or Discard to cancel them.
Exchange data with Excel
Filter the rows and fields to what you want.
Click Export Excel for a formatted workbook containing a hidden stable object key.
Edit only the unlocked green cells, then use Import Excel.
Click Review changes to compare old and new values, search the pending set, and exclude any change that should not be applied.
Click Accept. Unsafe or unmatched rows are skipped and marked in an .import-result.xlsx copy. Its RKCadTools Import Changes worksheet records each staged cell with its drawing, Plant row, class, property, previous value, new value, and source.
Review pipeline groups
In a 3D drawing, open PipeLine Manager beside Data Manager in Data & Control.
Choose 3D Pipeline Groups and Current drawing or Full project.
Edit writable fields in the table.
Use Review changes and Accept for staged edits, or select tagged pipeline rows and open Quick Iso or Production Iso.
Select pipeline rows once, then open Quick Iso or Production Iso with their line numbers preselected.
Pipeline Manager adds Quick Iso, Production Iso, and Lock Weld Numbers for selected 3D pipeline groups. Right-click a tag for Zoom to object or Assign. A Duplicate column and Duplicates only checkbox flag pipeline groups that span more than one drawing. Select a duplicate row and click Open Other Drawings to open each additional drawing and zoom to the matching lines. No database changes are made.
Search checks every loaded row but only the columns currently visible in the grid. Use spaces for AND, | for OR, quotes for exact phrases, or right-click the search box to insert a visible column name. Pasting rows or columns from Excel creates an OR list automatically.
Data Validator
Use this to compare property values across two or three data sources and find rows that disagree.
Size VS Size compares two Plant sources by Tag. Status and Only issues filter the visible result set; red cells show differing values.
P3DVALIDATOR P3DVAL
Compare P&ID data, 3D piping data or an external source configured in Data Bridge, including a SharePoint Excel workbook. Choose Data A and Data B for a two-way comparison. Add Data C to compare a third source.
Set up a comparison
Click Data Validator in the Data Manager panel.
Choose a source under Data A and a matching Key A field.
Choose Data B and Key B.
Optional: choose Data C and Key C for a three-way comparison.
Click Load / Refresh to pull field metadata.
Pair the fields to compare
Open the Fields to Compare tab.
Click Add mapping.
Pick the Data A property and the matching Data B (and optionally Data C) property.
Use the search boxes above the grid to filter long field lists.
Repeat for every property that should agree across the sources.
Narrow scope before validating
To check one saved project drawing, open it and select Active drawing only beside Save Selection. This limits the Plant rows in A, B and C to that drawing, including pipeline groups linked through a member. External lists stay complete. Save Selection remembers the option. When you switch drawings, click Validate again to check the new drawing with the same setup.
Open the Data A, Data B, or Data C tab.
Tick the classes you want to include in Database structure.
Use Exclude key values matching regex to drop unwanted keys (for example \? to skip placeholder rows).
Click Apply to refresh the preview.
Run validation
Click Validate.
Read the row count, mismatch count, and value cells in the result grid.
Use the Search box (space for AND, | for OR, quotes for exact phrases, Field:value for one column) and the Status filter to focus on specific issues.
Tick or untick rows in the first column to mark which results to act on or export.
Zoom and export
Select a result row.
Click Zoom A, Zoom B, or Zoom C to focus the linked Plant object in the drawing.
Click Export Excel to share the filtered list. The workbook keeps the row status colors and the per-cell agreement colors.
Click Clear Results to start over without losing the source selection.
Save and reuse a selection
Type a name in the Selection box at the top of the window.
Click Save Selection.
Pick the saved selection later to restore sources, keys, class filters, regex, mappings, and result columns.
Use Clear C next to Key C to drop Data C from the active setup and fall back to A vs B.
%APPDATA%\RKCadTools\SavedViews\Validator
Row color
What it means
Green
All mapped values agree across the chosen sources. Fully matching keys normally do not appear in the results grid, so you will rarely see a green row.
Pink
A mapped value disagrees somewhere. The cell colors below show which side.
Amber
The key is missing in at least one source, or the key field is empty.
Purple
The same key appears more than once on a side.
Value cell color
What it means
Green
This value matches at least one other source.
Red
This value differs from every other source. With three sources this is the odd one out; with all three red, no two agree.
No tint
The field is not mapped for this side, so nothing was compared.
The most recent result is cached under %APPDATA%\RKCadTools\Plant3DDataValidatorResults.json and reopens automatically next time you launch the validator. Use Clear Results to delete it.
Validate on a copied project before running the validator against large live data sets so unexpected scope or regex filters do not surprise the team.
Use this for fast property changes on selected objects.
The selected Pump has Nominal Diameter 100, Pressure Class 10 and Status New. Padlocks mark locked properties; no edit or Apply was performed for the screenshot.
Open Quick Properties
Click Quick Properties.
The palette opens immediately.
Select objects in the drawing to load their configured properties.
Edit an unlocked property, choose Apply, and verify the stored value.
QEDIT
Choose shown properties
Select an object first so the tool knows which Plant database and class to use.
Click Quick Settings in the Properties panel.
Pick the class or family.
Select which properties should appear.
QEDITPROPS
Set a value at the command line
Run QEDITSET.
Select one Plant 3D or P&ID object.
Pick the editable property by number.
Type the new value. It is written immediately, without opening the palette.
QEDITSET
Number nozzles
Select or pick the nozzles.
Click Nozzle Number.
Enter the starting number.
QEDITNUMBER
Number off-page connectors
Select or pick off-page connectors.
Click OPC Number.
Enter the starting connector number.
QEDITOPCNUMBER
Quick Properties can include editable line-group properties when the selected object belongs to a line group. Use Quick Settings to choose visible and read-only properties per class or family.
In P&ID, selecting a primary line segment can show both the selected Primary row and its related Pipeline Group row. Editable Pipeline Group properties can be changed directly from Quick Properties. Tags, formulas, counters, Plant 3D system fields, and acquired values without native Override support stay locked.
Acquired properties remain locked until Plant 3D reports that they can be overridden. Right-click an eligible value and choose Override property. Quick Properties switches and verifies Plant 3D’s native Override mode before writing; the yellow override state is stored in the project and survives AutoCAD restarts.
The Nozzle Number and OPC Number buttons are on the Tags panel and are shown in P&ID drawings.
Use this panel when assigning or checking Plant 3D tags.
This P&ID audit shows 21 items and six problem rows. Review Problems, then select a row to inspect Details before assigning a tag.
Assign a tag
Select the object.
Click Assign.
Fill in the tag and configured extra fields.
Confirm the Plant 3D tag command.
ATX_ASSIGN
Check tags in one drawing
Open the drawing.
Click Tag Audit and use the Active Drawing tab.
Review missing tags, duplicate tags, and question marks.
Use Assign to edit the selected tag. P&ID lines open Autodesk’s native Assign Tag dialog.
ATX_TAGAUDIT
Assign next available numbers
Click Assign Next.
Pick objects one after another.
The tool assigns the lowest available number for each tag prefix.
ATX_ASSIGNNEXT ATX_AUTONUMBER
Refresh acquired drawing data
Open Tag Audit on the Active Drawing tab.
Click Refresh Acquired.
Plant 3D refreshes acquired and calculated properties in the current drawing. Tags that use those properties are updated, and Tag Audit rescans when the command finishes.
This does not assign new tags or rebuild tags after tag-format changes. Collaboration and Vault drawings must be writable or checked out.
PLANTREFRESHACQPROPERTY
Replace existing tag numbers
Select the objects and click Renumber.
Review the confirmation explaining the left-to-right processing order.
The tool clears and replaces each number. If assignment fails, it restores the previous value.
ATX_RENUMBER ATX_CLEARNUMBER ATX_CLEARNUM
Check tags in the project
Open the Plant project.
Click Tag Audit and select the Project tab.
Review drawing-level and class-level tag status.
Double-click a drawing or use Open in Tag Audit for row-level fixes.
ATX_PROJECTAUDIT
Choose tag fields
Open Tag Settings and choose Visible Fields.
Choose P&ID or 3D Parts. Each scope has its own class tree and field configuration.
Choose which extra fields appear in the tag window for that scope.
Save the configuration.
ATX_CONFIG
Take over the native tag command
Open Tag Settings and choose Native Takeover.
When enabled, the native Assign Tag command opens Assign Tag Extended instead.
Choose Native Takeover again to switch back to the native dialog.
ATX_TAKEOVER
The Project tab can export the audit result and open drawings directly in the Active Drawing tab. Use the audit filters to control which source families and classes are included.
In Tag Audit, Assign Next is available only when all selected rows belong to Inline Assets, Instrumentation, or Equipment. It is hidden for pipelines, nozzles, connectors, annotations, mixed unsupported selections, and unknown source families.
Tag Audit, Renumber, and Assign Next are shown in P&ID drawings. The original Clear Number command remains available for command-line and macro compatibility.
Search narrows the audit to two pumps. The selected P-200-? has an empty Number; the image shows inspection before any correction.
Choose Source and Target after reviewing the connector details and drawing context. No suggested tag match was found here; the screenshot shows preparation before Connect.
Connect or review off-page connectors
Click OPC Manager.
Search or choose the drawing.
Review unconnected connectors and suggested partners.
Use Set as Source and Set as Target for connectors on different drawings, then review the pair before choosing Connect.
Read the refreshed status and save the affected drawings. To remove an existing pair, select a connected OPC and choose Disconnect.
PIDMANAGER
Review the project overview
Click OPC Overview.
Review drawing-to-drawing connector flow and unconnected connector counts.
Switch to Cluster Map when you need a draggable visual map of drawing relationships.
Open or zoom to a connector from the overview when a drawing needs correction.
P3DOPCOVERVIEW P3DOPC
OPC Manager and OPC Overview are docked palettes. They can stay open while you move between drawings and review connector status.
Find a part in a project spec, place it on a line, or keep frequently used fittings ready while routing.
Search visible columns to compare spec rows. No part is selected here, so Insert in Model is disabled.
P3DSPECBROWSERP3DSPECBARP3DQUICKACCESSP3DQUICKBAR
Search a spec sheet
Click Spec Browser in the 3D panel.
Choose the active spec or all registered specs and optionally filter by component type.
Search with spaces for AND, | for OR, quotes for exact phrases, or a column-qualified term such as Size:DN100. Right-click a column header to target it, or paste an Excel list.
Use Columns… to choose the visible result columns. Search and export use them in their current order.
Review matching component rows, part sizes, item codes, descriptions, and custom spec columns.
Insert or export results
Select a result and click Insert in Model, double-click the row, or drag it into the active Plant 3D model.
Snap to a matching open port, or pick a straight pipe to insert an inline fitting with matching run ends. Use Baseport to cycle the fitting end or branch used for attachment. Set the direction when prompted.
Click Export to Excel to create a formatted workbook from the visible result layout.
Place a part from Spec Bar
In a project piping drawing, open RKCadTools → 3D → Spec Bar. Leave Follow active routing spec and Follow routing size on to follow Plant, or choose a source spec and size yourself.
Choose a category or search for a part. All sizes beside Search widens a text search. Choose Selected size to keep your size filter. Check the end types and both connection sizes on a reducer or reducing tee. Enable Show part thumbnails for catalog previews.
Double-click the part and follow Plant’s placement prompts. Next time, double-click its category to place the last-used matching part. If several parts match and the previous part is unavailable, select a row.
Use Instruments for project and supplemental instrumentation parts, and Clamps for supports. Finish an active pipe route before inserting a clamp.
Give a placed component the connected line’s spec
In 1.3.8 Beta 13, leave Use connected line spec checked in either panel. It starts on and remembers your choice for this project and user across both panels.
For example, select an E10 valve and snap it to an E40 pipe. Once Plant connects it, the valve takes Spec = E40 even if E40 does not list that valve. Its size, geometry and ports come from the E10 part you selected.
Read the placement message. Spec Bar reports the result after placement or routing ends. Clear the checkbox to keep the source spec on future placements.
Free placement keeps the source spec. If the connection cannot be verified, or the target spec uses the same internal catalog record number for another part, the toolkit skips the change and explains why. Plant still checks size, end types and joint compatibility.
Spec Browser follows the spec files registered in the active Piping project database. If a registered spec or its companion .pspc database cannot be opened, use the Warnings button for the exact path and reason.
When the palette is narrow, Spec Browser switches to a compact layout: Spec and Type stay side by side, Search fills the next row, and Insert, Refresh, Export, and Columns move into the … menu. Selected part values start collapsed to preserve grid space. Compact and wide modes remember their own visible columns, order, and widths.
Share a model snapshot that a reviewer can open in a browser.
Open the model and choose Drawings & Delivery → 3D HTML, or run P3DWEBGLEXPORT. Export the selection, the drawing or the active Clipper region.
Choose the properties and colors to include, then save the HTML file. To show insulation in the export, make it visible in Plant before exporting. A jacket follows its component when the reviewer picks, hides or isolates it.
Open the file in a browser to search components, inspect properties, measure or add review marks. Use Save a copy to give the recipient an HTML file containing the annotations and named views.
Draw a continuous 3D polyline across different working planes.
Run RKUCSPLINE at the command line and pick the first point.
Pick the next vertex. To turn the working plane around the last vertex, choose X, Y or Z at the prompt. You can also hold Ctrl+Alt and press the axis letter. Each turn is 90 degrees about that local axis. Reset restores the starting orientation at the current vertex.
Use Length for a straight segment of a known length or Undo to remove the last segment. Press Enter to finish, choose Close to join the ends, or press Esc to discard the draft.
The finished object is an ordinary 3D polyline. Plant restores the starting UCS when the command ends. If a shortcut is already assigned, use the prompt options or run RKUCS_SHORTCUTS to check the assignments.
Cable Tray
Draw wire mesh trays, cable trays and cable ladders; place supports and export quantities.
Where: RKCadTools → 3D Piping → Cable Tray. Available in Plant 3D 2025–2027 on Windows; excluded from the 2024 build. Open a saved model in the active Plant project and work in model space with millimetres or inches (INSUNITS = 4 or 1).
The Cable Tray panel groups drawing, route edits, supports and quantity review. Select the image to view it at full size.
1. Choose a product and draw
Click Draw Cable Route.
Select Category: Wire Mesh Trays, Cable Trays or Cable Ladders. Choose Product series and Dimension / product; use Search sizes to narrow the list.
Choose Lightweight for everyday modelling, especially wire mesh trays. Use Detailed only for presentation views. Set Insertion point to Middle, Bottom, Left, Right or Top, then set the opening rotation.
Review the rotating product preview and click Draw. Pick the start and subsequent route points while checking the live preview.
Follow the command prompts: Finish/Enter commits the route, Undo removes the last accepted step and Esc cancels the current drawing action. Save the drawing normally.
The current workflow uses the CableTray product library. Available products and fittings depend on the selected series.
RKCADTOOLS_CABLETRAY_ROUTE
2. Continue or adjust a route
Use Continue, select an open end and pick the next route points.
Use Tray settings to change size, insertion reference or opening rotation.
Use Extend / Move → Extend to drag a straight or enter its final length in mm. Relative changes such as +200 or -100 are also available.
Use Move Support / Branch / Tee / Cross to slide the selected component along the tray. Review the preview before placing; Esc cancels.
Use the toolkit’s route editing commands to keep saved route data and geometry together.
Fittings → Bend starts at an open end. Branch connects to a continuous main straight; Edit Branch and Delete Branch manage that connection. Stock wire mesh crossings use two branches on opposite sides. Fitting-based series use their available tee, reducer or four-port cross.
Stock profile changes a stock run’s article, and Corner joints chooses Miter or Overlap for stock baskets. Route graphics switches Detailed/Lightweight without changing product dimensions or BOM quantities. Detailed wire mesh trays can make the DWG large in MB or heavy to work with; keep routes Lightweight during daily work and use Detailed only for presentation views.
Open Supports → Place Support. Search the family or article and inspect the insertion point in the preview.
For a suspended model, choose On CableTray — automatic underside placement and select a straight tray, or use manual placement. Other models show their applicable placement controls.
Set rod lengths, use equal lengths if appropriate, or choose the available roof-point workflow. Review placement before applying.
Use Edit Support for later adjustments and Delete support for removal.
Supports remain independent and do not automatically follow later tray changes. Check their position after modifying a route. Support spacing and load design remain engineering decisions.
Open Sizes / BOM or Manage sizes / BOM properties… in the route dialog. Select a series and component type. Use Add / copy size or Edit size, review dimensions, descriptions and item numbers, then Save series. Support articles are managed under Support families.
If the library is empty, check the configured CableTray and Support Library location and add or copy the required products before drawing.
RKCADTOOLS_CABLETRAY_LIBRARY
6. Review and export the bill of material
Click Bill of Material.
Check item numbers, Count, Length (m), Qty and Unit. Select a row to highlight matching components; use Clear highlight to remove the temporary highlight.
Use More columns for extra properties.
Click Export Excel… and save the .xlsx workbook.
The scope is the current drawing’s model space. Xrefs and nested block contents are excluded. Straight metres exclude bends; fittings and supports are pieces. Stock-only basket joints contribute straight material, not separate fitting counts. No stock rounding, waste, installation allowance or bend developed length is added. Fasteners and accessories are excluded unless independently placed.
RKCADTOOLS_CABLETRAY_BOM
Choose the product, insertion reference and display before drawing. Select the image to view it at full size.Automatic underside placement is shown for a suspended support; inspect the selected model’s controls. Select the image to view it at full size.Review the active drawing’s item groups, highlight model components and export an Excel workbook. Select the image to view it at full size.
Saved routes: the DWG geometry remains visible without RKCadTools. Creating or editing toolkit routes requires the plugin. Review your first route and quantities on a project copy.
Weld Manager
Choose weld classes and numeric series, then fill missing numbers or review a new sequence in the active 3D Piping drawing.
Automatic numbering is marked BETA in this build. With custom classes and series unchecked, all detected weld classes share one series per pipeline, starting at 1.
Before numbering: WeldNumber must allow manual entry. For ISO output, select ID: Weld Number Property for Weld ID (Shop) and/or Weld ID (Field) in Project Setup → Isometric DWG Settings → Annotations → Table ID’s. Automatic ISO IDs can display a different sequence.
Choose classes and numbering series
Open Numbering Settings.
Keep the default to number all detected weld classes in one shared series per pipeline, or enable Choose weld classes and numbering series.
Add a named series and check its weld classes. Multiple classes in one series share a counter; separate series have separate counters.
Set Start number. Review the numeric example and save.
Weld numbers are positive integers without leading zeros. Example: one shared series produces 1, 2; separate series can each start at 1. Use one shared series when numbers must be unique across classes. A class can belong to one series. Unselected classes are skipped.
WM_WELDSETTINGS
Lock missing weld numbers
Click Lock Weld Numbers.
Pick an object on the pipeline.
Review old and new numbers, class, row ID, Drawing No. and DWG filename in the preview. Apply the changes, or cancel to leave the drawing unchanged.
Review the result and save/check in through the normal Plant 3D workflow.
Existing values stay unchanged. Blank numbers continue above the highest matching number in each series on that pipeline in the active DWG. Numbers in other DWGs do not affect the counter. “Lock” fills values; it does not set a separate read-only flag.
WELDMANAGER_LOCKWM_LOCKWELDNUMBERS
Automatically number new welds
Enable Automatically number new welds after modeling commands in Numbering Settings.
Create new welds while modeling.
Check the automatic numbering result after the command ends.
Enable this in WM_WELDSETTINGS; no ISO, start point or prior Renumber From Point run is required. The same classes and series rules apply in the active DWG. Only new blank weld rows are numbered; existing numbers and older blank rows are preserved. Undo/Redo and failed or cancelled commands do not trigger numbering. Automatic numbering runs without a preview dialog after successful modeling commands. Commands without new Plant objects do not trigger a drawing scan, and completed objects leave the queue immediately. Numbering may be a separate undo operation.
Renumber from a point
Click Renumber From Point.
Pick an object on the pipeline and the start point.
Review Drawing No., DWG filename, class, row ID, old number and new number. Drawing No. falls back to the filename when unavailable.
Apply the plan or cancel without changing numbers.
This replaces existing numbers for the selected classes in the active drawing, using each series’ start number. Numbers in other DWGs do not affect this sequence. The existing command aliases remain available.
Lock All asks you to continue before filling blank numbers on all pipelines in the active drawing with your numbering rules. Existing values are kept.
Blank Numbers clears editable weld numbers on the selected pipeline for all weld classes, irrespective of class selections in Numbering Settings.
WM_LOCKALLWELDNUMBERSWM_CLEARWELDNUMBERS
Check weld numbers
Check Weld Numbers reports duplicates within each series on the pipeline in the active DWG. Existing 001 and 1 values represent the same number in that series.
WM_WELDDIAG
Drawing-based changes: only graphical welds in the active drawing are changed through Plant 3D’s API. The toolkit does not write directly to project databases; Plant manages the linked project data. Protected, acquired, calculated and generated WeldNumber fields are rejected. Test on a project copy first.
NULL, blank, or missing external values are ignored and never clear existing content.
Writable properties are applied even if another mapping is read-only or acquired.
Skipped read-only and acquired properties are listed in the completion report.
Selected components must use the same Plant class and project section. Configured component-property differences are handled as groups.
Set up a sync
Click Setup.
Create or select an Excel, SQLite, SQL Server, or OData data source.
Choose the table, view, or sheet.
Choose scope, classes, and conditions.
Map external columns or static values to Plant 3D or AutoCAD properties.
P3DBRIDGE_CONFIG
Preview before syncing
Click Preview.
Review the before→after grid of every change the sync would make.
Click Apply all to write every listed change. To write only selected changes, use Accept first and then Apply (N); close the window to discard the preview.
Apply uses the changes you reviewed for the original drawing. If a mapped worksheet or column has been renamed, correct the mapping and run the preview again.
P3DBRIDGE_PREVIEW
Manage data sources
Click Data Sources.
Choose Excel, Excel (SharePoint), SQLite, SQL Server or OData.
For SQL Server, choose Windows authentication to use your current account. For a SQL login, enter the server, database and user name, then choose Store password for this Windows user.
Preview the source rows before mapping.
P3DBRIDGE_DATASOURCES
Read a SharePoint workbook or OData feed
For Excel (SharePoint), copy the workbook’s full file URL from Details → Copy path in SharePoint. Paste it in File URL. Enter your organization’s Microsoft Entra settings and choose Sign in.
For OData, enter the feed address and select its authentication method. Use Advanced read options to select fields or filter the rows to download. Include the key fields and every field used in your mappings.
Choose Test and refresh local data. For a workbook, select the worksheet and header row. Preview the data before setting up the mapping. Refresh again if the local data used for sync has expired.
Use Sign out and clear local data when changing accounts. Sign in and refresh with the account that will run the comparison or sync.
Sync the active drawing
Open the drawing.
Confirm the setup is correct.
Click Sync.
P3DBRIDGE_SYNC
Sync open drawings
Open the drawings that should be processed.
Click Sync All Open.
Let the tool activate, save, and sync each drawing.
P3DBRIDGE_SYNCOPEN
Control sync order and matching
Use Enabled to keep a setup saved without running it.
Use Priority so lower-numbered configurations run first.
Use condition logic for all conditions or any condition.
Choose whether empty external values should be written or skipped.
Use Data Bridge carefully. Test on a copied project before changing live project data.
Safest first setup: start with one class, one unique key condition, and one non-critical property. Run Preview, check every before→after value, and keep Show Sync Preview enabled until the result is trusted.
Automatic sync configurations run with Preview, Sync, Sync All Open, or sync-on-open. Interactive lookup configurations run only from Choose Data and never participate in automatic sync.
Data Bridge uses two config files: a shared/admin file (Plant3DDataBridge.json) and a per-user file (Plant3DDataBridge.user.json). The dialogs open in the personal scope. To maintain the shared project setup, select Edit shared project config, check the displayed file path and save with write access to that file. Both are merged at sync time — data sources and configurations from both run together. By default both files are stored in a project-specific folder under %APPDATA%\RKCadTools\DataBridge\Projects. Use Settings → Shared Admin Folder to place the shared/admin Data Bridge file in <sharedFolder>\Projects\<projectName>\Plant3DDataBridge.json. A short project-ID suffix is added only when two different projects share the same name.
Create a box from selected objects, adjust its faces, and save the region for later review.
Create a region
Open Clipper and choose From selection.
Select the model objects and finish the selection to activate isolation.
Use Drag face or Box dimensions to adjust the region.
Enter a name, choose a scope and select Save as new. Use Save view to update the active region.
Switch views and restore
Open Quick Views, search or filter the saved list, then click a view to activate it. Restore saved camera controls the stored angle.
Restore model brings the full model back. Default isolation retains whole intersecting components; experimental face clipping is display-only and may leave custom Plant graphics whole.
FAQ: Why are xrefs not clipped in height? Set FASTSHADEDMODE to 0 to turn Fast mode off, then choose Apply isolation in Clipper.
Color 3D Plant objects by a property value while you review a piping drawing.
The shared Status set is read-only. Use Duplicate to Local to edit its value colors or fallback options.
Create and apply a set
Open a 3D Piping drawing and choose Color Rules → Settings.
Click New, name the set, and choose whether values come from a component property or a pipeline group property.
Choose Color by. Use Scan drawing to collect values, or add them yourself. Assign colors individually or use Auto-assign palette.
Choose optional colors for empty values, unlisted values, and non-Plant objects. Set non-Plant transparency if needed.
Click Save, then select the set from the Color Rules ribbon menu. Use Show Legend to review the active colors; choose Color Rules Off to return to normal display.
Local, shared, and plotting
Local sets can be edited. Shared sets are read-only in the list; use Duplicate to Local to make an editable copy.
Colors are display-only by default. Tick Include in plot only when the plotted output should use the set.
Color Rules apply to 3D Piping drawings, not P&IDs, orthos, or isometrics. The display colors do not change Plant project properties.
Linked P&ID Publish
Publish a P&ID set with clickable off-page connections in a multi-sheet PDF.
Choose the sheet scope and whether OPC connections should become PDF links.
Publish a linked PDF
Click Linked P&ID Publish on the ribbon.
Choose All project P&IDs to include paper layouts from registered P&IDs, including closed drawings, or choose Open drawings for the standard AutoCAD Publish sheet list.
Leave Link OPC connections selected when reviewers need clickable off-page connections.
Click Open Publish. Review sheets, order, page setups, and PDF settings in AutoCAD Publish, then publish a multi-sheet PDF in the foreground.
Open the resulting PDF and test the links between sheets.
Before you publish
All-project scope selects paper layouts and excludes Model. Every selected project DWG must be available locally and have a paper layout.
If the output PDF is locked by a viewer, the linked result is saved as a separate _linked.pdf file. Check the report beside the output if a sheet or link could not be processed.
RKCADTOOLS_LINKEDPIDPUBLISH
Revision Manager
Keep drawing revision history and mapped title blocks in sync.
Add a revision note, then save and synchronize it to the drawing title block.
Add a revision
Open Revision Manager or choose Add Revision Note from its ribbon dropdown.
Review the next revision code and date; enter the description and initials.
When working in Revision Manager, click Add to stage the row, then Save & Sync to write the DWG history and update configured paper-space title blocks.
Use Edit or Delete to maintain the history. Run Sync again after reviewing any manually changed title-block attributes.
Configure the title block
Open Revision Manager Configuration and select the title block.
Choose alphabetic or numeric numbering, define the revision fields, and map each visible revision row to its title-block attribute tags. Auto-map can detect numbered tags.
Save as user to test locally, or Export a shared administrator configuration.
Example title block after revision B is added: the earlier A entry has moved up one visible row, and the new entry appears below it. Row order follows the configured title-block mapping.
Full revision history: A title block shows only as many revision rows as it has configured slots. When older revisions move beyond those visible rows, they remain in the drawing history and can still be viewed in Revision Manager.
Map the fields and revision slots used by your project title block.
RKREVISIONRKREVADDRKREVCONFIGRKREVSYNC
Drawing List Generator
Build an Excel drawing list from registered Plant 3D project drawings.
Select project drawings, scan their saved DWGs, review the preview, and export the list.
Create and export a list
Choose a configured profile from the Drawing List Generator ribbon dropdown.
Select drawings or folders in the active project’s drawing tree.
Click Scan and Preview. Review the status and the drawing number, description, latest revision, date, description, and initials columns configured for the profile.
Clear Include for rows you do not want, then click Export to Excel to create the .xlsx file.
Administrator setup
In Settings → Drawing Lists → Configure Drawing Lists, create a profile and map Excel columns to title-block attribute tags or Revision Manager fields. Choose Revision Manager fields such as revision code, date, description, and initials to bring the latest revision into the drawing list. The generator reads the latest saved revision from the drawing history; when no RKCadTools history exists, it can use the newest visible mapped title-block row. Save the profile in the shared admin folder so it appears in the ribbon.
Save edits in source drawings before scanning. Unavailable DWGs, missing title blocks, and missing revision values appear as preview warnings; the scan does not save the drawings.
RKDRAWINGLIST
Create Drawing
Create registered P&ID, Ortho, and 3D drawings with independent project-specific numbering.
Create a project drawing
Open Create Drawing and choose P&ID Drawing, Ortho Drawing, or 3D Drawing.
Use the next number (highest existing number plus the configured step), choose an available gap, or enter another file name.
Choose a destination from that drawing type’s searchable folder tree. The last location is remembered separately per type, and New Folder can create a child through Plant 3D.
A file name already used by the same registered drawing type is blocked.
Click Create, or Create & Continue to create the drawing and keep the dialog open for the next one.
Select P&ID, Ortho, or 3D and assemble an independent name from ordered segments.
Use Fixed/Separator for constants, FreeText or Choice for user input, and ProjectLookup or Date for generated values. Add at most one Counter when automatic next-number and gap suggestions are wanted; omit it for counterless names.
Edit or reorder segments, select folder or whole-project number scope, and review the generated read-only pattern.
Enable each required drawing type. Existing registered names are scanned within the matching project part.
Test the local draft, then export and deploy the shared JSON through the normal ACC/Vault project administration workflow.
RKDRAWING_CONFIG
The same segment definitions build the Settings preview and the Create Drawing form. FreeText becomes a validated text field. Each Choice row has a description shown in the dropdown and a separate value inserted into the file name. Project/date/counter values are generated automatically.
The Drawings panel shows only drawing types with a complete enabled configuration and a loaded matching project part. RKCadTools checks the file name again immediately before Plant 3D’s project API registers the drawing.
The number is a convenience suggestion, not a central reservation. Verify the workflow on a copied project before using it in production.
Utilities
Use this for drawing utilities and toolkit settings.
Tool
Use it for
Command
Activate License
Activate the RKCadTools license on this workstation. The button is shown while no valid license is installed. RKLICENSE_STATUS shows the current license state.
RKLICENSE_ACTIVATE
Export DWG
Export selected P&ID or Plant 3D drawings to plain AutoCAD DWG copies.
P3DEXPORTACAD
Update Blocks
Update attributes, batch-edit attribute values with Excel, or redefine an existing block from a source DWG.
P3DUPDATEBLOCKATTRIBUTES
Settings
Open, export, import, and edit project and user configuration files.
P3DUTIL_SETTINGS
Update from one source block
Open Update Blocks.
Choose the source drawing and click Pick Block.
Pick the title block or block reference that contains the attributes to copy.
Edit the New Value column and tick the attributes to update.
Select target drawings. Add DWGs, add a folder, or load paths from a .txt, .csv, or .lst list when needed.
Choose whether to update the source drawing, update all matching blocks in each drawing, and save drawings after the update.
Click Update Attributes and review the result grid.
Batch edit with Excel
Add the DWG files to edit.
Pick the source block from the first DWG, or type the exact block name.
Click Read Attributes to preview values across the files.
Export the preview to .xlsx, edit the attribute values, and import the edited workbook.
Review the diff. Red rows are missing files or missing blocks; green rows contain changes that can be applied.
Click Apply Changes and export the CSV result log when a record is needed.
Redefine blocks from a source DWG
Open Update Blocks and switch to Redefine Blocks.
Add the target DWGs where an existing block definition should be replaced.
Pick the target block from the first target DWG, or type the exact block name.
Pick the source DWG and the source block definition that should replace the target.
Click Preview Targets to check missing, read-only, and matching drawings before writing.
Click Redefine Blocks and review the result grid. Export the CSV log when a record is needed.
Shared and project files
Data Bridge is project-specific. Its default shared/admin JSON and per-user JSON are stored under %APPDATA%\RKCadTools\DataBridge\Projects\<projectName>-<hash> so Plant 3D cleanup does not remove them.
When Shared Admin Folder is set, this project’s shared/admin Data Bridge file is read from <sharedFolder>\Projects\<projectName>\Plant3DDataBridge.json. A project.identity.json marker verifies the Plant project identity, and a short project-ID suffix is used only for duplicate project names. Existing hash-named folders are not migrated automatically. The matching Plant3DDataBridge.user.json file stays in each user’s AppData folder.
Admin vs user configs
Features that support both scopes use two config files, a shared/admin file (<Feature>.json) and a per-user file (<Feature>.user.json). Personal settings go to the user file. Data Bridge can also save shared changes when an administrator selects Edit shared project config.
At runtime both files are merged: lists (data sources, configurations, columns) are concatenated, dictionaries (class entries, scope settings) are unioned by key with user entries winning on conflict, and scalar flags take the user value when present.
Feature
Shared (admin)
Per-user (plugin writes here)
Data Bridge
Plant3DDataBridge.json
Plant3DDataBridge.user.json
Assign Tag Extended
AssigntagExtended.json
AssigntagExtended.user.json
Quick Edit
Plant3DQuickEdit.json
Plant3DQuickEdit.user.json
Data Manager
Plant3DDataManager.json
Plant3DDataManager.user.json
P&ID Connector Helper
PIDConnectorHelper.json
PIDConnectorHelper.user.json
An admin can redirect all shared/admin settings in one step via Settings → Shared Admin Folder → Set Location. RKCadTools then reads admin-managed views from <sharedFolder>, feature admin configs from <sharedFolder>\Admin\<Feature>.json, and Data Bridge admin configs from <sharedFolder>\Projects\<projectName>\Plant3DDataBridge.json. Edits made in the personal scope go to .user.json files.
Saved views (admin + user)
Saved views (Data Manager views, Export selections, Validator profiles) also support the admin/user split. User views are saved in the personal views folder (%APPDATA%\RKCadTools\SavedViews) unless Saved Views points to another personal or team folder. Admin-managed views come from the root of the Shared Admin Folder and are loaded read-only alongside each user’s personal views. Views with the same name in the user folder override admin views.
Data Manager views are grouped by data source below the views root:
DataManager\PnId — standard P&ID views.
DataManager\Piping — standard 3D Piping views.
DataManager\PnIdPipelineGroups — P&ID Pipeline Group views.
DataManager\PipingPipelineGroups — 3D Pipeline Group views.
For admin-managed views, these folders are below the Shared Admin Folder. Personal views use the same structure below the configured Saved Views folder. A personal scope folder is created automatically when its first view is saved; an administrator can create the corresponding shared folder when publishing an admin view.
User files
User-specific JSON files are stored under %APPDATA%\RKCadTools. This includes Quick Properties, Assign Tag Extended, Data Manager, Cross Navigation, and PID Connector Helper settings. Data Bridge user files are stored per project under %APPDATA%\RKCadTools\DataBridge\Projects\<projectName>-<hash>. In Data Bridge, check the scope and displayed file path before saving changes to a personal or shared setup.
Update Blocks can write changes back to DWG files. Test on copied drawings first when setting up a new title block, block redefine, or batch edit.
Reports
Build Excel reports, keep their history and compare revisions in Excel Compare.
Build reports and keep project history in Plant 3D, then open Excel Compare in your browser to review two revisions.
Build a report
Save the source drawings and open Reports from the ribbon.
Choose an installed Autodesk Report Creator template.
Select Whole project, Current drawing or Selected drawings.
Click Build report. Review the completed Excel output and its entry in history.
Autodesk Report Creator must be installed. Reports use saved project data; unsaved drawing edits are not included.
Compare report revisions in your browser
Select the newer report in history. Reports shows it as New report and finds the previous successful run with the same template, Report Creator version and drawing selection as Old report.
Click Open Excel Compare to open Excel Compare in your default browser.
Use Show file beside each report to select it in Explorer. Drag the earlier file into Old report and the selected file into New report on the web page.
Choose the worksheets, header rows and matching key columns. Review changed, added and removed rows, then download the comparison results and save them where you need them.
The first run has no previous matching report. You can also choose any two exported reports in Excel Compare. Use a stable, unique key: changing a tag used as a key can appear as a removed and added row.
Files are processed in your browser and are not uploaded. Comparison results download through the browser; Reports keeps the generated report history and does not save comparison downloads automatically.
Report storage: Use Settings → Reports to choose the output location. The default is the project’s Related Files/RKCadTools/Reports folder. Changing the location leaves existing history in its original folder.
RKREPORTRKREPORT_SETTINGS
P&ID Symbol Browser and Palette Builder
Place a project symbol or organize reusable palettes for a project or company.
Place a P&ID symbol
Open a registered P&ID drawing and choose Admin Tools → Symbol Browser or run RKPIDBROWSER. Search by class, style or block name. Choose Find from drawing to identify the style of an existing symbol. Double-click a style or drag it into the drawing, then complete Plant’s insertion prompts.
Star frequently used styles, return to Recently used or choose Add to Palette Builder to add a style to your draft palette.
Build a portable palette
Open a registered P&ID drawing and choose Admin Tools → P&ID Palette Builder.
Arrange the project symbols with headers and separators, or use Import XTP to bring in an existing palette. Review the mapped symbols and icons.
Validate the palette against the current project setup.
Use Save Configuration for the draft and Build Portable Package for the standard XTP palette package.
Test in Plant 3D
On a copy of the project, choose Test in Plant 3D to load a native preview palette. Open Tool Palettes with Ctrl+3 and place test symbols through Plant 3D.
After changing the draft, choose Update test palette. Use End test to remove preview palettes. Objects you placed remain in the drawing; remove them through the normal drawing workflow. Testing does not replace saving or exporting the palette.
Publish to Project makes the complete palette set available to users of the active project. To distribute a company set across projects, configure Shared Location in Settings and choose Publish Company Palettes. Check the destination before confirming. Publishing replaces the complete set at that destination. Other RKCadTools users can open the published palettes in a P&ID drawing with Ctrl+3.
RKPIDBROWSERRKPIPALLETTEBUILDERRKP3DPIDPALETTE
Troubleshooting
Common problems and what to do next.
The ribbon is missing
Type RKCADTOOLS_RIBBON to rebuild the ribbon from the loaded DLL. If that does not help, close Plant 3D, rerun the installer and reopen the program. AutoCAD cannot replace a DLL that is already loaded.
A tool says there is no Plant 3D project
Open a Plant 3D project and make sure the active drawing belongs to that project.
Data Manager opens drawings while browsing
Turn off Zoom on selection. When this is on, selecting a row can open the drawing and zoom to the object.
A field is locked
Plant 3D controls which properties can be changed. Tags must be changed with ASSIGNTAG or PLANTTAG. System-managed fields may stay locked.
Settings are not where I expected
Many features have a shared <Feature>.json and a personal <Feature>.user.json. In Data Bridge, the active scope shows the file you are editing. Feature files live under %APPDATA%\RKCadTools by default. Data Bridge is project-specific and defaults to %APPDATA%\RKCadTools\DataBridge\Projects\<projectName>-<hash>. Use Settings → Shared Admin Folder to point admin views, admin configs, and Data Bridge admin configs to one shared folder. Use Settings → Saved Views when you only want to change where personal saved views are stored.
Data Validator shows no results or far too many
Check that Key A, Key B, and (if used) Key C all point to fields that contain the same kind of identifier. Then check the class filter on each Data tab and the Exclude key values matching regex box. Click Load / Refresh after changing sources so metadata is reloaded before validating.
I want to drop Data C without losing my A and B mappings
Click Clear C next to Key C. The validator falls back to a 2-way A vs B comparison. FieldC entries on existing mapping rows are wiped so old C values are not silently re-applied if you pick a new Data C source later.
The build folder cannot be overwritten
AutoCAD has loaded the DLL from that folder. Close AutoCAD, or build to a fresh folder and load that new DLL.
Your privacy, your choice
We use necessary cookies for website functions and to remember your choice. With your permission, Burst collects usage statistics using browser and device information. Statistics stay disabled until you accept Analytics.
Cookie Policy
Necessary cookies support website functions and remember your choices. Optional Analytics uses Burst device fingerprinting for usage statistics; it does not store an analytics cookie. You can reject optional categories and continue using the website. Change or withdraw your choice through Cookie settings. See our Cookie Policy for details.
Necessary cookies help make a website usable by enabling basic functions like page navigation and access to secure areas of the website. The website cannot function properly without these cookies.
Marketing controls advertising and cross-site tracking cookies. No marketing cookies are listed in the current website cookie inventory. Burst usage statistics is controlled separately under Analytics.
Optional Burst usage statistics uses browser and device information to recognise returning browsers. No analytics cookie is stored. It starts only after you accept Analytics; withdrawing consent stops future tracking.
Optional preferences would remember settings such as language or region. No optional preference cookies are listed in the current website cookie inventory.