Choose your weld classes. Set up the numbering.
Use one shared series or separate counters for different weld classes. Set a positive start number, then preview missing-number assignments or a new sequence from a picked point.
Choose classes and number welds

Weld Manager detects graphical welds and their pipeline in the active drawing. By default, all detected weld classes share one series per pipeline, starting at 1 with digits only. Ordinary Lock previews blank-number assignments and preserves assigned values. Apply the plan, or cancel without changing the drawing.
ISO uses model numbers
series and start
renumbering
save and create ISO
What “Lock” means
Lock assigns missing WeldNumber values. It does not set a separate read-only flag. Changing a rule does not rewrite existing numbers; use Renumber From Point when you deliberately want to replace them.
Start on a project copy
Only welds in the active drawing are changed through Plant 3D’s drawing-based API. Plant manages the linked project data; RKCadTools does not write directly to project databases. Numbering is scoped to each pipeline and series in the active DWG. Weld numbers in other DWGs are neither looked up nor reserved. Test the complete workflow on a project copy before production.
Allow manual model numbers and use them on the ISO
The model property must allow manual entry. Read-only, acquired, calculated, generated, counter and system properties are rejected. If protection cannot be verified, the write is skipped and reported.
The ISO style’s annotation setting determines whether it displays model numbers or generates its own IDs. This is separate from editing the model property.
- Open your project and the 3D Piping drawing.
- Confirm the weld classes’ WeldNumber properties allow manual editing in Plant Project Setup.
- For each ISO style you use, open Project Setup → Isometric DWG Settings → Annotations → Table ID’s.
- Select Weld ID (Shop) and/or Weld ID (Field), then choose ID: Weld Number Property under Attribute Text.
- Apply the settings and confirm the result on a test ISO.
Automatic numeric or alphabetical ISO IDs can show a different sequence even when the model’s WeldNumber is editable. RKCadTools does not automatically detect or change every ISO style. Autodesk explains the ISO numbering options.
Choose classes and shared or separate series

- Open Weld Manager → Numbering Settings, or run
WM_WELDSETTINGS. - Leave Choose weld classes and numbering series unchecked for the all-classes default. To customize numbering, check it.
- Select or add a named series, then check the weld classes that belong to it. Class names come from your project.
- Set the start number and review the displayed numeric example.
- Save settings. A class can belong to only one series; unselected classes are skipped.
| Field | Meaning | Example |
|---|---|---|
| Series name | A unique name identifying the shared counter. | Workshop welds |
| Weld classes | Exact project classes included in this series. | Buttweld + Tapweld |
| Start number | A positive starting number for a new series or renumbering. | 1 |
Example: shared or separate counters
| Setup | Result on one pipeline |
|---|---|
| Both classes in one series, start 10 | 10, 11, 12 across both classes. |
| Buttweld and Tapweld in separate series, each start 1 | Buttweld: 1, 2. Tapweld independently: 1, 2. |
| Unique numbers across weld classes | Use one shared series. Separate series may contain the same number; duplicate checks are within each series. |
Class names in these examples are illustrative; use the exact names shown by your project. Every series is per pipeline in the active DWG. Another pipeline or DWG has its own counter; numbering does not continue across DWGs.
Rules preserve existing values
Lock continues above the highest positive integer in the series on that pipeline in the active DWG, or starts at the configured start number if no higher value exists. WeldNumber stores positive integers without leading zeros. Older text-format and digit-width settings are ignored; existing assigned values are preserved. Settings are saved per user and project under Related Files → Custom plugins.
Fill missing numbers and check the result
- Click Lock Weld Numbers or run
WM_LOCKWELDNUMBERS. - Pick an object on the pipeline.
- Review the preview with drawing, class, row ID, old number and new number. Apply the changes, or cancel to leave the drawing unchanged.
- Review assigned numbers, excluded classes and failed writes in the command-line result.
- Run Check Weld Numbers (
WM_WELDDIAG) to inspect duplicates. - Save/check in through the normal Plant 3D workflow, then create the ISO with your configured style.
Lock All (WM_LOCKALLWELDNUMBERS) applies the same rules to every pipeline present in the active drawing after a Continue/Cancel prompt, followed by a preview for each pipeline with planned changes. For multiple selected pipeline groups, use Pipeline Manager.
Existing duplicate numbers are reported and preserved. Numeric comparisons treat existing 001 and 1 values as the same number in a series. Check Weld Numbers (WM_WELDDIAG) and numbering counters use only graphical welds in the active DWG. Pipeline Manager weld-status counts can include project data from other drawings. The same number may occur in another DWG; uniqueness across drawings is not enforced.
Number new welds while modeling
Beta feature: the illustrated build marks automatic numbering BETA. Test its behavior on a project copy before relying on it for production.
- Open Numbering Settings and enable Automatically number new welds after modeling commands.
- Create welds while modeling. Only new objects from successful commands are queued; ordinary commands without new Plant objects trigger no drawing scan.
- After the command ends, inspect the automatic numbering message and the resulting properties.
Automatic numbering uses the same classes and series as manual Lock in the active DWG. Enable it in WM_WELDSETTINGS; no ISO generation, start point or prior Renumber From Point run is required. It numbers only newly created rows with blank WeldNumber values. Existing numbers, older blank welds, Undo/Redo and cancelled/failed commands are not processed. Automatic numbering runs after a successful command without a preview dialog; review its result in the command line. Completed welds are removed from the queue immediately, and unresolved Plant links receive limited retries. Automation is off by default.
Automatic numbering may form a separate undo operation from the modeling command. Check Undo behavior on your project copy and disable automation before workflows where that separation is undesirable.
Review a new sequence from a picked point
- Click Renumber From Point.
- Select an object on the pipeline, then pick the start point.
- Review Drawing No., DWG filename, class, row ID, old number and new number. Drawing No. falls back to the DWG filename when unavailable.
- Apply the plan, or cancel to keep all existing values.
- Check the result before saving/checking in.
Numbering follows the piping graph from your picked point. Each configured series uses its own start number. Only selected weld classes in the active drawing are renumbered; numbers in other DWGs are not looked up or reserved and do not affect this sequence.
The button was previously called Lock From Point. Its command aliases WELDMANAGER_LOCKFROMPOINT and WM_LOCKWELDNUMBERSFROMPOINT still work. Planned targets are checked for manual editability before any numbers are cleared. If a later write fails, the tool attempts to restore the original values and reports restoration failures.
Blank Numbers is a separate action
Blank Numbers (WM_CLEARWELDNUMBERS) clears editable weld numbers on the chosen pipeline for all weld classes, regardless of your numbering selections. Use it only when you intend to clear those values.
Quick troubleshooting
A weld does not receive a number
It must be graphical, linked to the pipeline in the active drawing, included in your selected classes, and have an editable WeldNumber. Ordinary Lock only fills blanks. Check the command-line result for exclusions or rejected writes.
Automatic numbering does not run
Enable Automatically number new welds after modeling commands in WM_WELDSETTINGS, then create new welds in the active DWG. Existing blank welds need ordinary Lock. Check class selections, editable WeldNumber and the command-line result. Delayed Plant data links are retried; if retries are exhausted, use WM_WELDDIAG and Lock to inspect and fill remaining blanks. A start point and ISO generation are not prerequisites.
The ISO numbers differ from the model
Check that the actual ISO style uses ID: Weld Number Property for the required Shop/Field annotation. Automatic numeric/alphabetical ISO IDs generate their own numbering.
Changed settings did not change existing numbers
This is intentional: Lock preserves existing values. Use Renumber From Point and review the proposed replacements.
Two different classes both have number 1
If they belong to separate series, this is allowed. Put them in one series for a shared counter when numbers must be unique across classes.
Pipeline Manager still shows missing welds
Status counts all detected welds. Classes deliberately excluded from numbering can remain blank. Use Quick Refresh if the status is stale and inspect your class selections.
The field is acquired, calculated or automatically generated